Files
ulweb/backend/.dockerignore
ulhub 21f5a04133 Tie points to locator serial numbers and store receiver telemetry
Field setups often relay through a phone/gateway that owns the MQTT
connection, so the publishing credential and the instrument are now
separate concepts:

- Points messages carry a "serial" identifying the locator receiver;
  unknown serials are auto-registered as devices in the publisher's
  org (name "Locator <serial>"). Device.mqttUsername is now optional
  and serialNumber is unique per org.
- LocatePoint gains standard receiver telemetry: frequencyHz,
  currentMa, signalDb, gainDb, locateMode (PEAK/NULL/BROAD_PEAK/SONDE),
  phaseDeg, compassDeg, distortionPct, plus GPS quality columns
  vAccuracy, satellites, hdop. All optional; raw payload still kept.
- Migration hand-edited to preserve the generated geom column and its
  GIST index (Prisma diff wanted to drop both).
- REST create/point DTOs, map tooltips, job-detail latest-point
  readout, devices settings form, seed, and the sample publisher all
  carry the new fields.
- Added .dockerignore for backend/web: COPY . . was clobbering the
  image's freshly generated Prisma client with the host's stale
  node_modules, breaking image builds after schema changes.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-14 14:58:12 +00:00